5TJI

Ca2+ bound aplysia Slo1


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg28.663
r_long_range_B_refined23.495
r_long_range_B_other23.493
r_scangle_other16.576
r_mcangle_it13.899
r_mcangle_other13.897
r_dihedral_angle_3_deg11.527
r_dihedral_angle_4_deg9.186
r_scbond_it8.989
r_scbond_other8.988
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg28.663
r_long_range_B_refined23.495
r_long_range_B_other23.493
r_scangle_other16.576
r_mcangle_it13.899
r_mcangle_other13.897
r_dihedral_angle_3_deg11.527
r_dihedral_angle_4_deg9.186
r_scbond_it8.989
r_scbond_other8.988
r_mcbond_other8.103
r_mcbond_it8.102
r_dihedral_angle_1_deg4.632
r_angle_refined_deg0.861
r_angle_other_deg0.771
r_chiral_restr0.047
r_bond_refined_d0.006
r_gen_planes_refined0.003
r_bond_other_d0.001
r_gen_planes_other0.001
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Ca2+ bound aplysia Slo1
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles60000
Reported Resolution (Å)3.8
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC4
Map-Model Fitting and Refinement
Id1
Refinement SpaceRECIPROCAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value160
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)1.4
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification22500
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND4
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTRELION
FINAL EULER ASSIGNMENTFREALIGN
CLASSIFICATIONRELION
RECONSTRUCTIONFREALIGN
MODEL REFINEMENTREFMAC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION638000